This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty, single-phase, maintenance bypass / power output distribution system. This system, hereafter referred to as the POD, provides high-quality maintenance by pass capability for all micro UPS products up to and including 3kVA.The POD is designed in accordance with the applicable sections of the current revision of the following standards. Where a conflict arises between these standards and statements made herein, the statements in this specification shall govern. The POD is stand alone UL listed. The POD units can be used with any manufactures UPS that meets the UL standards listed below.
This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty, single-phase, maintenance bypass / power output distribution system. This system, hereafter referred to as the POD, provides high-quality maintenance by pass capability for all micro UPS products up to and including 3kVA.The POD is designed in accordance with the applicable sections of the current revision of the following standards. Where a conflict arises between these standards and statements made herein, the statements in this specification shall govern. The POD is stand alone UL listed. The POD units can be used with any manufactures UPS that meets the UL standards listed below.
Liebert GXT3-MT on-line uninterruptible power supply (UPS) is a compact mini-tower model ideal for protecting sensitive electronics in a non-rack environment. The UPS offers intelligent monitoring and network management functions.Flexibility- Compatible with backup generator — handles frequency variations and other power fluctuations that occur during generator operation.- Offers a variety of monitoring options via Liebert IntelliSlot interface.- Provides six battery backed outlets to accommodate protection for more equipment.Higher Availability- Protects against and conditions all forms of power anomalies.- Assures continuity of power to critical loads during system maintenance or in case of internal fault with internal automatic and manual bypass.- Operates with a wider input voltage window for fewer transfers to battery, saving battery wear and tear.- Allows fast and easy maintenance with user-replaceable hot-swappable batteries.- Notifies users with advance early warning of UPS status via automatic and manual battery test feature.- Operates compatibly with Liebert MicroPOD maintenance bypass and power output distribution module.Lowest Total Cost Of Ownership- Corrects for frequency variations without switching to battery, resulting in longer battery life.- Protects your investment with a standard two-year warranty with paid shipping both ways. Also available with optional extensions of one year or three years.Ideally Suited For- PCs- Network workstations- Test and diagnostic equipment
These premium UPS replacement battery cartridges breathe new life into UPS systems suffering from expired or weak internal batteries. Each replacement battery cartridge is carefully screened and certified to meet or exceed original specifications, and ships ready for installation into your UPS system. Reusable packaging holds expired batteries for recycling center delivery. See the UPS replacement battery web page to confirm compatibility and quantity required.COMPATIBLE WITH SU1500XL, SU2200XLA (See the RBC selector to verify compatiblity with your UPS).
Thermaltake Toughpower Grand RGB power supply unit 850 W 24-pin ATX ATX Black
Thermaltake Toughpower Grand RGB power supply unit 750 W 24-pin ATX ATX Black
Global Power Supply unit for Jabra Speak 810. The unit comes with easy-to-click-on exchangeable wall plugs included for EU/NA/UK/HK/AU.
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Tripp Lite single phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU lighted digital display enables visual monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 20A single phase 120V Monitored Power Distribution Unit / PDU (agency derated to 16A continuous)- Attached NEMA L5-20P input plug with NEMA 5-20P adapter and 12ft / 3.6m line cord- 1U horizontal rackmount installation format supports installation in 2 or 4 post equipment racks- 8 NEMA 5-15R outlets- Lighted display reports output power consumption in amps- Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading via network or secure web browser interface with options for user specified alarm and notification thresholds- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements.- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Included cord retention brackets keep vital network equipment plugged in and continuously powered- TAA Compliant Version Available - Order Tripp Lite PDUMNH20TAA
Axiom RE2-12VCC-AX mobile device charger Tablet Black USB Auto
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA