Genuine APC RBC(TM) are tested and certified for compatibility to restore UPS performance to the original specifications.
"APC NetShelter Rack PDU Advanced, Metered, 5.0kW, 1PH, 208V, 30A, L6-30P, 40 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.Maximum Outlet DensityAll models include 40, 42, or 48 outlets to accommodate even the highest density of devices, allow for more installation flexibility, and provide room for growth within the PDUs power capacity limits.Space SavingWith such high outlet counts and power capacity, NetShelter Advanced Rack PDUs are designed to maximize space with their single width form factor, often allowing for fewer PDUs to accommodate the same number of devices and power requirements.High Power CapacityModels now available to provide up to 34.6kW (derated to 80% capacity per National Electric Code (NEC) for North America) and up to 43.5kW for other countries to ensure support for most any density deployment and help minimize the number of PDUs needed to do so.APC Locking Power Cord CompatibleFree up space and secure power cords between rack-mount PDUs and attached IT equipment with this easy-to-use cord retention method. Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet; the ""locking"" feature is enabled when used with NetShelter Rack PDU Advanced to reduce the probability of accidental power cord disconnect.Circuit Breaker MonitoringAllows total load across each circuit breaker to be monitored for potential overload and can be configured to provide notification in the event of a circuit breaker trip.Alternating PhaseNetShelter Rack PDU Advanced incorporates an alternating phase design on 3 phase models whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU. This alternating phase layout facilitates better power cord management and more intuitive load balancing versus traditional PDU solutions where outlets are grouped by phase at the top, middle, and bottom of the PDU.60ºC (140ºF) Operating TemperatureRated and approved to operate up to 60C (140F) at full load, NetShelter Rack PDU Advanced ensures reliability and availability even in today's high density deployments.Power SharingRack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU. Network communication is uninterrupted, attached sensors still operate, and alarm traps remain available.Hydraulic Magnetic Circuit BreakersProvide increased availability by maintaining trip current over a wide temperature range.Live Swap Network Management CardThe Network Management Card (NMC) can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event.Color Coded OutletsTo simplify deployment, outlets on the PDUs are color coded by breaker on 1 phase models and color coded and/or labeled by breaker and input phase on 3 phase models.Environmental Sensor SupportTwo environmental sensor ports allow for optional sensors (sold separately) to be connected. Sensors available within the NetSelter Rack PDU Advanced portfolio include temperature, temperature/humidity, temperature (3 sensors)/humidity, rope leak detection, and a door contact switch. Also available is an expansion hub to allow connection of up to three sensors providing the ability to manage six separate sensors from one rack PDU. Sensor availability expected late 2022.Wide Offer BreadthMetered, Switched, and Metered-by-Outlet with Switching functionality are available across all power configurations ranging from 5kW up to 34.6kW to meet the need for most deployments.Network CascadingConnect and manage up to 32 PDUs from a single IP address to simplify and speed PDU deployment while reducing networking costs associated with having a dedicated network connection for each PDU.US Based ManufacturingUS based manufacturing enables better product availability and ability to offer configure-to-order (CTO) products (optional and subject to pricing and leadtimes) including different cord lengths, plug types, and PDU chassis color.Dual RatedFor data center deployments across multiple regions, select models are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.Flexible PDU MountingWith pre-installed mounting pegs, NetShelter Rack PDU Advanced can be quickly installed in the toolless mounting holes of the rear accessory channel in a NetShelter SX and many 3rd party cabinets. Mounting pegs can be repositioned to the side of the PDU to rotate the orientation of the outlets 90 degrees and face the back of the cabinet for better clearance from device chassis or mounting rails.4-in-1 Combination OutletsOffering unparalleled flexibility, 4-in-1 combination outlets which can be used as either C13 or C19 enable a single PDU outlet layout to support various rack layouts and configurations. In addition, the same 4-in-1 combination outlets also serve as high temperature C15 and C21 outlets for devices with C16 and C22 power cords. With 4-in-1 combination outlets redeployment of a PDU with new rack layout or configuration is easy and straightforward, often preventing the need to remove and discard a PDU upon IT refresh.Color LCD DisplayNetShelter Rack PDU Advanced provides a rich color LCD display for local management and control at the rack.Dual Network PortsA second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy.1% Metering AccuracyProviding the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring.Gigabit Ethernet ConnectivityProvides Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center.Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time."
Rack PDU 2G, Metered, ZeroU, 30A, 100-120/200-240V, (16) 5-20R (12) C13 (2) C19APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
Intuitive LCD interface Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. Predictive replace battery date Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Energy meter Provides actual kilowatt hours of usage for energy conscious users. Outlet group control Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups). Sequenced shutdown and restart Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups). Pure sine wave output on battery Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. Single switched outlet group Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. Wide input voltage range Designed for harsh electrical environments to save battery life. StruxureWare Central compatible Enables centralized management via StruxureWare Central. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance High online efficiency Reduces utlility costs, generates less heat. LED Indicators Provide easy-to-read status of the unit and utility power conditions. Cold-start capable Provides temporary battery power when the utility power is out. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Disconnected battery notification Warns when a battery is not available to provide backup power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Audible alarms Provides notification of changing utility power and UPS conditions User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) USB connectivity Provides management of the UPS via a USB port (not available on all models). Serial Connectivity Provides management of the UPS via a serial port. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Network manageable Provides remote management of the UPS over the network. Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. Predicitive failure notification Provides early-warning fault analysis ensuring proactive component replacement. Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Disconnected battery notification Warns when a battery is not available to provide backup power. Network manageable Provides remote management of the UPS over the network. Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. LED status indicators Quickly understand unit and power status with visual indicators. Serial Connectivity Provides management of the UPS via a serial port. USB connectivity Provides management of the UPS via a USB port (not available on all models). Disconnected battery notification Warns when a battery is not available to provide backup power. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement. Resettable circuit breakers Enables a quick recovery from overload events. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Guaranteed UPS compatibilityTested and approved to restore the performance of your APC UPS. Maintains UPS safety certifications (UL, VDE, CSA) and lifetime equipment protection policy (as applicable).Long battery lifeDesigned by APC by Schneider Electric exclusively for APC UPS's for complete compatibility with the intelligent battery management system.Fully assembled for easy hot-swap installationAPC RBCs are safe, reliable and contain a minimum number of connections saving valuable time. Because APC RBCs are hot-swappable, no network downtime is required in order to install them.Re-usable packaging with clear instructions on how to properly dispose of spent batteries.Convenient, easy and green.Prepaid postage to a nearby recycling partnerInsures that almost 100% of the old battery is recycled, protecting the environment.
"APC RBC35. Battery technology: Sealed Lead Acid (VRLA), Product color: Black. Weight: 2.2 lbs (1 kg), Dimensions (WxDxH): 2.64 x 5.28 x 2.6"" (67.1 x 134.1 x 66 mm)"
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
19 inch Rack-MountableSupplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternate power source.Resettable circuit breakersEnables a quick recovery from overload events.Vertical mounting capability.Horizontal mounting capability.
"APC NetShelter Rack PDU Advanced, Metered, 8.6kW, 3PH, 208V, 30A, L21-30P, 42 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected."
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced