GTS RBC33- UPS battery Sealed Lead Acid (VRLA) 12 V 9 Ah
GTS RBC4- UPS battery Sealed Lead Acid (VRLA) 12 V 12 Ah
GTS RBC62-1U- UPS battery Sealed Lead Acid (VRLA) 6 V 9 Ah
GTS RBC6- UPS battery Sealed Lead Acid (VRLA) 12 V 12 Ah
Spectralink 84642473 mobile device charger Mobile phone Black USB Indoor
Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Portsmith Technologies PSCMC67UE battery charger
Spectralink 2200-37036-701 mobile device charger Black Indoor
APC IT Power Distribution Module 3 Pole 5 Wire 30A L21-30 200cmA touch-safe Power Distribution Module (including circuit breaker, power cord, power connection, and circuit monitoring) that eliminates the need for hot work or shutdowns during expansion of the power distribution system.Built-in Web/SNMP managementFull-featured management via a Web browser as well as comprehensive management from a Network Management System.Low Cost Power DistributionProvides a number of outlets to bring power to rack equipment at an affordable price.Smallest footprintMinimizes your real estate expensesSystem mobilityPDU equipment can easily be relocated to accommodate a changing data center environment.Local and web-based monitoringStatus available to customers both in the data center and remotelyMultiple distribution optionsSuperior design flexibility enables a wide range of customer requirements to be addressed.LED status indicatorsQuickly understand unit and power status with visual indicators.Modular Power Accessories Features & BenefitsSafetyEnhance user safety with isolation at all touch points and with positive locking mechanisms that reduce the risk of accidental disconnectionManageabilityPower monitoringMeasure and monitor power consumption and usage with branch circuit monitoring and output metering, which are included at no extra costQuick status information LEDsAccess status information about the performance of the Power Distribution ModuleConvenienceToolless installation of breakersInstall factory-assembled Power Distribution Modules in under ten minutes - no tools are requiredGlobal product offeringStandardization of the power distribution system across all corporate locations is easy - a variety of 1-phase and 3-phase Power Distribution Modules address the unique power requirements of data centers around the world
GTS APCRBC110- UPS battery Sealed Lead Acid (VRLA) 12 V 9 Ah
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA