Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. - 12.6kW 3 phase 208V Switched Power Distribution Unit / PDU with built-in web/network interface - Attached 50A Hubbell CS8365C 208V 3 phase input; 10 ft. / 3m cord - 0U, 70 inch / 178cm vertical form factor - 24 switched 208V outlets (21 C13, 3 C19) in 3 single phase load banks - Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis - Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets - Network interface provides PDU control and data regarding input voltage, per-outlet and per-phase load levels - Digital display with scroll-buttons supports per-outlet or per-phase load levels, IP-address self-identification and 180 degree display rotation - Supports user-specified alarm notification thresholds - In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors - DHCP/Manual configuration support - 10/100 Mbps auto-sensing - Real-time clock backup maintains the time of day and date even if the PDU is unpowered - Tiered access privileges allow an administrator and a guest to login via web browser - Alert notifications via email or SNMP traps offer immediate event notification - Firmware upgrade ability supports future product enhancements - Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Fully compatible with FREE PowerAlert Network Management System / NMS Software - Included cord retention brackets - Toolless mounting in button-mount compatible racks - Nut-and-bolt mounting support for other racks
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for each output phase, breakered load bank and individual outlet.- 28.8kW Switched 415/400/380V input 240/230/220V output PDU with built-in web/network interface- Hardwire (3P+N+E) 415/400/380V 3 phase input- 0U, 70 inch / 178cm vertical form factor- 24 switched 240/230/200V outlets (12 C13, 12 C19) in 6 separately breakered 20A single phase load banks- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-breaker and per-phase- Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
Tripp Lite Metered Power Distribution Units / PDU systems continuously report output load level in amps to help network managers prevent overloads and plan for future growth. Supplies equipment with continuous power from any protected UPS, generator or mains input power source. Highly reliable design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 30A single phase 120V Metered Power Distribution Unit / PDU (Agency derated to 24A continuous)- Two-digit lighted meter reports total PDU input current in amps- Attached L5-30P 30A 120V input plug with 15 ft. / 4.5m line cord- 1U horizontal rackmount format installs in one rack space- 12 NEMA 5-15/20R outlets- Outlets are arranged in two loading banks, each with separate 20A breaker protection- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Back panel grounding lug- TAA Compliant Version Available - Order Tripp Lite PDUMH30TAA
High-capacity 3.3/3.8kW PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. Digital display and Ethernet interface monitor load levels to prevent overloads that cause downtime.- Two single-phase L6-20P inputs with 10 ft. cords- L6-20R outlet for connecting single device or 0U vertical PDU- Automatic transfer switching within 1–5 ms- Ethernet network interface for remote access- Digital display for real-time status monitoringThe PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-20R outlet—perfect for connecting a single device or a 0U 208/240V PDU with an L6-20P plug. Dual 10-foot input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).Primary and Secondary Inputs for Power Redundancy- Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations- Dual 10 ft. input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources- Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to separate UPS systemsBuilt-In L6-20R OutletConnects a single device or indirectly powers equipment through a 0U 208/240V PDU with L6-20P input (sold separately)Automatic Transfer Switching (ATS)- Dynamic solid-state (TRIAC) automatic transfer switching- Switches to secondary power source if primary source fails or becomes unstable- 1–5 ms transfer time ensures uninterrupted operation of connected equipment- Built-in processor prevents switching if secondary source is unavailable or of lower quality than primary sourceMultifunction Digital Display- Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factorAdvanced Network Monitoring- Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP- Real-time load/current data with billing-grade accuracy (+/- 1 percent)- Automated alerts help prevent overloads, power loss and downtime- Optional ENVIROSENSE module (sold separately) monitors temperature and humidityBroad Communications Compatibility- Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksMounts Horizontally in 1U of Rack Space- Compatible with EIA-standard 19 in. 4-post racks and rack enclosures- Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
Tripp Lite single phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU lighted digital display enables visual monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 15A single phase 120V Monitored Power Distribution Unit / PDU (agency derated to 12A continuous)- Attached NEMA 5-15P input plug with 12ft / 3.6m line cord- 1U horizontal rackmount installation format supports installation in 2 or 4 post equipment racks- 8 NEMA 5-15R outlets- Lighted display reports output power consumption in amps- Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading via network or secure web browser interface with options for user specified alarm and notification thresholds- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements.- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Included cord retention brackets keep vital network equipment plugged in and continuously powered- TAA Compliant Version Available - Order Tripp Lite PDUMNH15TAA
Tripp Lite single phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU lighted digital display enables visual monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 20A single phase 120V Monitored Power Distribution Unit / PDU (agency derated to 16A continuous)- Attached NEMA L5-20P input plug with NEMA 5-20P adapter and 12ft / 3.6m line cord- 1U horizontal rackmount installation format supports installation in 2 or 4 post equipment racks- 8 NEMA 5-15R outlets- Lighted display reports output power consumption in amps- Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading via network or secure web browser interface with options for user specified alarm and notification thresholds- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements.- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Included cord retention brackets keep vital network equipment plugged in and continuously powered- TAA Compliant Version Available - Order Tripp Lite PDUMNH20TAA
2-2.4kW Single-Phase ATS rack PDU (rPDU) with Primary and Secondary Inputs for Power RedundancyRecommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-ft. (3.7 m) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.Switches from Primary to Secondary Power Source in MillisecondsDynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption.An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership.Check Essential Functions at a GlanceA front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.Easy to Install Horizontally in an EIA-Standard 19 in. RackThis ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.TAA-Compliant for GSA Schedule PurchasesThe PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
The PDUMH15HVAT 2–2.4kW Single-Phase 200–240V Local Metered Automatic Transfer Switch / ATS PDU enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features 10 C13 outlets.Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.Built-in slot supports the optional WEBCARDLX (sold separate), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.
The PDUMVR30HVNETLX 5/5.8kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19). LEDs indicate each outlet’s on/off power status, and you can monitor each outlet’s power consumption remotely or via digital display. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform interface enables full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital LED meter allows you to monitor each bank’s load in real time to ensure the PDUMVR30HVNETLX is used at maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for each output phase, breakered load bank and individual outlet.● 28.8kW Switched 415/400/380V input 240/230/220V output PDU with built-in web/network interface● Hardwire (3P+N+E) 415/400/380V 3 phase input● 0U, 70 inch / 178cm vertical form factor● 30 switched 240/230/200V outlets (24 C13, 6 C19) in 6 separately breakered 20A single phase load banks● Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis● Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outlets● Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-breaker and per-phase● Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)● In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors ● Local display supports electronic 180 degree display rotation for overhead or under-floor input cable orientation● Supports user-specified alarm notification thresholds● DHCP/Manual configuration support● 10/100 Mbps auto-sensing● Real-time clock backup maintains the time of day and date even if the PDU is unpowered● Tiered access privileges allow an administrator and a guest to login via web browser● Alert notifications via email or SNMP traps offer immediate event notification● Firmware upgrade ability supports future product enhancements● Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTPP, DHCP, BootP, NTP protocols● Fully compatible with FREE PowerAlert Network Management System / NMS Software● Included set of Plug-lock inserts keep C14 and C20 power cords solidly connected to PDU outlets● Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)● Switched 28.8kW 3-Phase 415/400/380V input 240/230/220V output PDU● Reports voltage & load per-outlet or per phase via ethernet interface● 1% billing-grade accuracy; Digital display reports detailed status information● 70in / 1778mm 0U vertical format; Toolless button-mount installation ● 24 C13 & 6 C19 single phase outlets; Plug-lock cable retention inserts● Hardwire 3 phase inputPackage Includes● Switched, vertical rackmount PDU with pre-installed mounting buttons ● 24 C13/C14 and 6 C19/C20 Plug-lock cable retention inserts ● Spare installation buttons (2 9mm / 4 6mm), Mounting brackets ● Configuration cable ● Owner's manual