The UNI Series laser-cut connector panels feature knockouts designed to accept a number of connectors, including XLR and Neutrik. The innovative design allows mounting of both male and female connectors to the same holes simply by knocking out the correct pattern. Made from one-piece flanged steel, black powder coat finish.
Cooling panel with control and display; 50 CFM at 24 dBThe two rackspace Ultra Quiet Fan Panel System provides smart cooling and monitoring to ensure a reliable installation in areas where fan noise is not an option, including boardrooms, classrooms, offices, houses of worship, etc. Thermostatic, proportional speed DC fan control ensures ultra quiet operation by varying fan speed based on enclosure temperature. Overtemp notification, local and remote, offers additional operation monitoring. A unique feature of the system provides notification in the event of fan failure via a local display or remote signal to an external alarm device. 50 CFM cooling capacity Digital processor varies fan speed based on enclosure temperature for ultra quiet operation Front panel rack temperature and alert display provides instant system status On-board digital processor monitors rack temperature via external sensor Local and remote notification of over temperature and fan fault can be sent to a control systemCooling panel rated 50 CFM at 24 dBIntelligent thermostatic proportional controlLocal and remote overtemp notification, with local display110V input voltage
Vent blockers are used to prevent the recirculation of hot air between top-mount fans and nearby vent openings. Vent blockers should be placed over the enclosure’s vents located on the upper front of the enclosure, upper sides, and upper rear door (depending on enclosure). This will ensure that heated enclosure air will be forced out through the top-mounted exhaust fans instead of re-circulating, keeping equipment cool.
Vent blockers are used to prevent the recirculation of hot air between top-mount fans and nearby vent openings. Vent blockers should be placed over the enclosure’s vents located on the upper front of the enclosure, upper sides, and upper rear door (depending on enclosure). This will ensure that heated enclosure air will be forced out through the top-mounted exhaust fans instead of re-circulating, keeping equipment cool.
Vent blockers are used to prevent the recirculation of hot air between top-mount fans and nearby vent openings. Vent blockers should be placed over the enclosure’s vents located on the upper front of the enclosure, upper sides, and upper rear door (depending on enclosure). This will ensure that heated enclosure air will be forced out through the top-mounted exhaust fans instead of re-circulating, keeping equipment cool.
Designed to organize and protect cabling between racks. Smooth, steel cable fingers are placed in rackspace increments for complete control of access locations.
The VDS shelf is a partially vented mounting solution for most deep equipment. This shelf has a front to rear mounting adjustment range from 23-1/2” to 32”. NOTE: Fits in racks with a minimum 23-1/2” from front to rear rail.
Choose this versatile rack for applications where a protective enclosure is not required. The VPM series accommodates all depths of equipment, and can be used either as a horizontal mount under a desk or table, or vertically as a wall mount.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA