Streamline capacity planning and power management with the CyberPower PDU83107 switched metered-by-outlet 3-Phase PDU. Ideal for data centers and network closets, this unit provides outlet-level power monitoring in real time, along with individual outlet control for remote reboots, load shedding, controlled power-cycling, and more.The PDU83107 supports inputs between 200-240V and includes 30 IEC-320 outlets. Other features include ultra-low power consumption, multi-color outlet LEDs, an interactive digital display with selectable background color, high operating temperature range, built-in web interface, and power event notifications. The CyberPower PDU83107 is protected by a three-year limited warranty.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Ultra-low Power ConsumptionConsumes less than 5W, resulting in less heat generation and lower energy costs.Multi-color Outlet LEDsAllows for easy identification of power phases, especially in a dimly lit rack environment. The individual outlet LED will turn red when there is an alert.Digital DisplayProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.Multi-color LCD BackgroundUser selectable background color on digital display allows for easy classification of PDU based on application. The LCD turns red when there is an alert.High Operating Temperature RangeOperates in data center hot aisle up to 140˚F (60˚C).Switchable OutletsProvides local and remote control for individual and multiple outlets. Local control: turn on/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on/turn off, schedule power on/off sequencing, and disable unused outlets.Per Outlet Power MeteringProvides information on the amount of power being drawn from each outlet, each circuit, and the PDU as a whole.CyberPower Management ConsoleA hardware interface built into Monitored and Switched PDUs. Its functionality includes the ability to switch PDU outlets on and off, reboot connected equipment locally or remotely, schedule power cycling of attached equipment, and perform other tasks, such as load monitoring and event logging.Remote and Local MonitoringEnables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients.Automatic Event NotificationsProvide immediate updates about power events via email, SMS text, or SNMP traps.Switch-Free DesignSafeguards against accidental power shut down.Upgradeable FirmwareDownloadable improvements (firmware updates) to programs that run the PDU.Long Input Power CordReaches distant power sources, allowing the PDU to be placed where it’s needed.Cord Retention TraySecures power cords, keeping them organized and accessible. Helps cords stay plugged in.Durable Metal HousingProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.Network-Grade Plugs and OutletsHighly-durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.Three-Year Limited WarrantyCovers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.
Product OverviewThe CyberPower RB12120X2B UPS replacement battery cartridge restores life to UPS systems with internal batteries that have become weak or completely depleted. The RB12120X2B 12V/12AH contains (2) two batteries, certified to meet or exceed original manufacturer specifications. All replacement cartridges come with leak proof sealed lead acid batteries that are pre-assembled for easy installation. Each CyberPower replacement battery cartridge ships with reusable packaging that can be used for delivery of expired batteries to a suitable recycling center. The RB12120X2B comes with instructions, recycling information, and an eighteen-month warranty.Sealed Lead-Acid BatterySupplies high surge currents, provides robust power-to-weight ratios, and is cost-effective.Maintenance-Free Battery FluidNever requires replacement.Leak-Proof CasingProtects the sealed lead-acid battery and prolongs battery life.User-Installable CartridgeAllows for quick and convenient installation; each cartridge is pre-assembled.Reusable PackagingProvides for conveniently delivering expired batteries to a recycling center. After installing the new cartridge, place the old one in the reusable packaging.OEM CertifiedCyberPower batteries meet or exceed original manufacturer specifications.Eighteen-Month WarrantyCovers defects in materials and workmanship in the product under normal use and conditions within eighteen months of the purchase date. See warranty for details.
The CyberPower Smart App Online OL10KRT is a 6U rack/tower double-conversion UPS. It provides sine wave output to multiple types of critical IT infrastructure requiring seamless power protection. The OL10KRT is generator compatible and delivers consistent 200-240 V power with zero-transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected.The OL10KRT features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable), and it has a RMCARD205 pre-installed network card. Smart-battery management charging technology increases battery life by up to 50%. Fast-charge technology helps replenish battery charge from 0-90% in five hours, regardless of the number of Extended Battery Modules (EBM) connected. The energy-saving GreenPower UPS™ ECO Mode allows the UPS to reach up to 97% efficiency to reduce power consumption and thermal dissipation.This UPS can use the BP240VL3U01 extended battery module for more runtime. The OL10KRT comes with a three-year warranty (including batteries) and a $300,000 connected equipment guarantee.Double-Conversion TopologyProvides consistent, clean, and nearly perfect sine wave output power, regardless of the condition of input power. UPS systems with this technology operate on isolated DC power 100% of the time and have a zero-transfer time because they electronically switch to battery (vs. using relays which can take 4-12 ms to switch). Double-conversion UPS systems are designed for high-end system components, enterprise servers, lab equipment, and other sensitive electronic devices.Sine Wave Output Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies.Removable LCD Control PanelDisplays 24 UPS status readings and allows configuration of 27 operation settings. The onboard event log will record and display the five most recent UPS system events. The LCD control panel can be removed and mounted in a more convenient location, up to ten feet away from the UPS (with optional DB-26 cable). Users can manage, setup, and control various operation settings, can scroll through multiple UPS status readings and run select UPS diagnostic tests.Multiple Language OptionsThe LCD control panel can be configured to English, Spanish, French, or German for use in multiple countries.Extended Battery Module (EBM)Add runtime by connecting more EBMs. The Smart App Online series of UPS systems allow for up to ten EBMs to be connected in a daisy-chain.Fast Charge TechnologyEnables Smart App Online UPS systems with multiple EBMs to charge batteries from 0-90% capacity in five hours. This is possible thanks to the built-in charger in each EBM.Smart Battery Management (SBM)Extends the service life of Smart App Online UPS batteries and reduces excessive heat during charge cycles by using a three-stage charging process. The first stage charges the battery to full capacity. The second stage enters float mode. The third stage turns the charger OFF to allow the batteries to naturally discharge (rest) for up to 27 days or until they reach a low-voltage set point. SBM continuously monitors the UPS to restart the charge cycle as needed, ensuring that runtimes are maintained.GreenPower UPS™ ECO ModeImproves UPS efficiency up to 97% to reduce electrical and cooling costs.Hot-Swappable BatteriesEliminate downtime related to UPS maintenance for continuous power availability.Generator CompatibleDisregards rapid changes in input frequency like those found in the output waveform of some generator sets. This allows the UPS to continue to operate in normal Online Mode vs. switching to Battery Mode when the power source is a generator set.Converter ModeProvides the ability to set the UPS output frequency (50 Hz or 60 Hz), regardless of the input frequency. This is beneficial where the connected equipment must operate on a different frequency than provided by local electric utility.Local and Remote ManagementMonitor and manage the UPS system locally via USB or serial connection, or remotely via the pre-installed RMCARD205 network card. Access UPS status, configuration settings, event logs, and status records, and more. Users can also setup email notifications.Rack or Tower InstallationAll the hardware accessories to rack mount the UPS in a standard 4-post 19” rack, or install as a tower unit, is included at no extra cost.PowerPanel® Business Edition SoftwareA robust and feature rich power monitoring and management tool for physical or virtual environments, PowerPanel Business Edition offers local (Agent) or remote (Client) functionality to automate graceful shutdown of IT equipment. Installing PowerPanel Business Edition Center provides centralized monitoring and management of PPBE Agents and Clients on the local network in addition to all CyberPower devices. PPBE is FREE for download on the Downloads tab above.Three-Year WarrantyCyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date.Connected Equipment GuaranteeCyberPower will repair or replace properly connected equipment if it is damaged by a power surge.
The CyberPower 18-outlet (6 Front and 12 Rear) rack mount basic power distribution unit (PDU20BT6F12R) provides 120V 20A output. It distributes power to 18 NEMA 5-20R receptacles from a single NEMA L5-20P twist lock plug, with unfiltered electrical pass-through. Designed for datacenters and other electrically demanding applications, this unit has a rugged, industrial-grade metal housing and a 15-foot AC power cord. It can be mounted either horizontally or vertically, includes a cord retention tray and is ETL/RoHS certified. A lifetime warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.- 18 NEMA 5-20R output receptacles (6 Front/12 Rear)- Single NEMA L5-20P twist lock plug- 20-amp electrical capacity with circuit breaker- 120V AC - 50/60Hz- 1U rack mount- 15-ft. power cord
The CyberPower Smart App Online OL8KRT is a 6U rack/tower UPS with double-conversion. It provides sine wave output to multiple types of critical IT infrastructure requiring seamless power protection. The OL8KRT is generator compatible and delivers consistent 200-240 V power with zero-transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected.The OL8KRT features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable), and it has a RMCARD205 pre-installed network card. Smart-battery management charging technology increases battery life by up to 50%. Fast-charge technology helps replenish battery charge from 0-90% in five hours, regardless of the number of Extended Battery Modules (EBM) connected. The energy-saving GreenPower UPS™ ECO Mode allows the UPS to reach up to 96% efficiency to reduce power consumption and thermal dissipation.This UPS can use the BP240V30ART3U or BP240VL3U01 extended battery module for more runtime. The OL6KRT comes with a three-year warranty (including batteries) and a $300,000 connected equipment guarantee.Double-Conversion TopologyProvides consistent, clean, and nearly perfect sine wave output power, regardless of the condition of input power. UPS systems with this technology operate on isolated DC power 100% of the time and have a zero-transfer time because they electronically switch to battery (vs. using relays which can take 4-12 ms to switch). Double-conversion UPS systems are designed for high-availability applications, precise output voltage regulation (±2%), generator set compatibility, environments with poor power quality, and other sensitive electronic equipment.Sine Wave Output Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies.Removable LCD Control PanelPanel displays 24 UPS status readings and allows configuration of 27 operation settings. The onboard event log will record and display the five most recent UPS system events. The LCD control panel can be removed and mounted in a more convenient location, up to ten feet away from the UPS (with optional DB-26 cable). Users can manage, setup, and control various operation settings, can scroll through multiple UPS status readings, and can run select UPS diagnostic tests.Multiple Language OptionsThe LCD control panel can be configured to English, Spanish, French, or German for use in multiple countries.Extended Battery Module (EBM)Add runtime by connecting more EBMs. The Smart App Online series of UPS systems allow for up to ten EBMs to be connected in a daisy-chain.Fast Charge TechnologyEnables Smart App Online UPS systems with multiple EBMs to charge batteries from 0-90% capacity in five hours. This is possible thanks to the built-in charger in each EBM.Smart Battery Management (SBM)Extends the service life of Smart App Online UPS batteries and reduces excessive heat during charge cycles by using a three-stage charging process. The first stage charges the battery to full capacity. The second stage enters float mode. The third stage turns the charger OFF to allow the batteries to naturally discharge (rest) for up to 27 days or until they reach a low-voltage set point. SBM continuously monitors the UPS to restart the charge cycle as needed, ensuring that runtimes are maintained.GreenPower UPS™ ECO ModeImproves UPS efficiency up to 96% to reduce electrical and cooling costs.Hot-Swappable BatteriesEliminate downtime related to UPS maintenance for continuous power availability.Generator CompatibleMode of operation in which the UPS disregards rapid changes in input frequency like those found in the output waveform of some generator sets. This allows the UPS to continue to operate in normal Online Mode vs. switching to Battery Mode when the power source is a generator set.Converter ModeProvides the ability to set the UPS output frequency (50 Hz or 60 Hz), regardless of the input frequency. This is beneficial where the connected equipment must operate on a different frequency than provided by local electric utility.Local and Remote ManagementMonitor and manage the UPS system locally via USB or serial connection, or remotely via the pre-installed RMCARD205 network card. Access UPS status, configuration settings, event logs, and status records, and more. User can also setup email notifications.Rack or Tower InstallationAll the hardware accessories to rack mount the UPS in a standard 4-post 19” rack, or install as a tower unit, is included at no extra cost.PowerPanel® Business Edition SoftwareA robust and feature rich power monitoring and management tool for physical or virtual environments, PowerPanel Business Edition offers local (Agent) or remote (Client) functionality to automate graceful shutdown of IT equipment. Installing PowerPanel Business Edition Center provides centralized monitoring and management of PPBE Agents and Clients on the local network in addition to all CyberPower devices. PPBE is FREE for download on the Downloads tab above.Three-Year WarrantyCyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date.Connected Equipment GuaranteeCyberPower will repair or replace properly connected equipment if it is damaged by a power surge.
CyberPower Power Distribution Unit (PDU) provides additional outlets for managing your rackmount power needs.This 12-outlet (6 Front and 6 Rear) rack mount power distribution unit (PDU) provides 120V 20A output. It distributes power to 10 NEMA 5-20R receptacles from a single NEMA 5-20P input, with unfiltered electrical pass-through. Designed for datacenters and other electrically demanding applications, this unit has a durable metal housing and a 15-foot AC power cord. It can be mounted either horizontally or vertically, includes a cord retention tray and is ETL/RoHS certified. A 3-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
Designed for datacenters and other electrically demanding applications, the CyberPower MBP63A2 Maintenance Bypass Power Distribution Unit (MBP PDU), allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS. The MBP63A2 provides 208V nominal output to (1) NEMA L6-20R, (1) NEMA L6-30R and (1) Hardwire Terminal Block receptacle.Depending on UPS model, either a 3.3-foot AC cord or hardwire terminal block connects to the output power of the UPS. The UPS draws input power from the MBP63A2 separate from the outlets or terminal block for connected devices. When the switch on the front of the MBP63A2 is turned from Normal to Bypass, or from Bypass to Normal, the power that the MBP supplies to connected devices moves from one input power source to another. The LED display indicates which power source is active.Rugged, industrial-grade metal housing protects the MBP63A2. With a 2U form factor, this PDU can be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration. The MBP63A2 is UL and RoHS compliant. A three-year limited warranty covers the PDU.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Maintenance BypassQualified personnel can use the bypass feature to disconnect the PDU from the UPS without disrupting power to connected equipment. This feature allows connected equipment to operate seamlessly during maintenance periods, battery replacement, or UPS installation.Manual Bypass SwitchWhen the Manual Bypass Switch is turned to Normal, connected equipment is supplied by UPS output. When the Manual Bypass Switch is turned to Bypass, connected equipment is supplied by utility power.MBP Detection CableCommunicates directly between the UPS and Maintenance Bypass PDU to safely coordinate the bypass switch operation. When the PDU bypass switch operation is initiated by removing the cover, the MBP Detection Cable sends a signal to the UPS to internally transfer to bypass mode to prevent UPS damage.Network-Grade Plugs and OutletsHighly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.2U Form Factor & Mounting HardwareThe 2U form factor is made to be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration.Durable Metal HousingProtects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.
Smart App Online UPS | Network, Servers and DatacenterThe CyberPower Smart App Online OL1000RTXL2U rack/tower uninterruptible power supply (UPS) with LCD control panel and pure sine wave output safeguards mission-critical servers, data center and telecom equipment, VoIP and internetworking hardware that require seamless power correction. Its Double-Conversion topology is generator compatible and delivers consistent and clean AC power with zero transfer time, protecting connected equipment and preventing costly business interruptions. Auto-bypass insures connected equipment continues to operate seamlessly when an overload or internal fault is detected.Configurable GreenPower UPS™ ECO Mode improves UPS efficiency to 93% and reduces electrical and cooling costs. Smart Battery Management (SBM) uses a 3 cycle charging mode to improve battery life while reducing heat being generated.The LCD control panel provides 43 different settings to check status and customize the operating parameters for the OL1000RTXL2U, plus it can be removed and mounted separately from the UPS for ease of use regardless of where the UPS is installed. Functions include menus for checking power status on (19) different parameters, (23) settings for setup, control and testing of the UPS and (1) selection for event logging. With a DB26 cable (sold separately) the LCD control panel can be removed from the UPS and relocated up to 10ft. away from the UPS for ease of viewing when installed in hard to reach locations.The UPS incorporates microprocessor-based fully digital control and includes PowerPanel® Business Edition providing the user unsurpassed flexibility and control. An optional SNMP/HTTP Remote Management adapter (RMCARD302) supports remote management and control of the OL1000RTXL2U through a standard web browser.The OL1000RTXL2U unit has a capacity of 1,000VA/900Watts (0.9 power factor) that can be configured for an output of 100V, 110V, 115V, 120V and 125V +/- 2%. It features eight (8) outlets with NEMA 5-15R receptacles and maintenance-free, hot swappable, user-replaceable batteries. This unit offers connectivity via one (1) HID USB, one (1) DB9 serial and one (1) emergency power off (EPO) port. Network grade surge suppression and EMI/RFI filters increase the immunity of the load to noise disturbances. The runtimes are expandable by adding a hot swappable, user replaceable BP36V60ART2U Extended Battery Module (EBM).
A compact UPS with standby topology, the CyberPower Ecologic EC450G provides battery backup (using simulated sine wave output) and surge protection for desktop computers, workstations, networking devices, and home entertainment systems. During power interruptions, the EC450G offers reliable power protection and battery backup. When the battery backup detects that the computer is off or in sleep mode, computer peripherals connected to the ECO Mode, surge protected outlets will be automatically turned off, reducing power usage and lowering energy costs (USB connection required). The EC450G comes with a three-year warranty (including coverage of batteries) and a $100,000 Connected Equipment Guarantee.Battery BackupSupplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.Surge ProtectionDiverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.Standby TopologyEnsures that when incoming power drops below or surges above safe voltage levels, the UPS switches to DC battery power and then inverts to AC power to run connected equipment.Simulated Sine Wave OutputUses pulse wave modulation to generate a stepped, approximated sine wave to supply cost-effective battery backup power for equipment that does not require sine wave output.GreenPower UPS™ High-EfficiencyReduces power consumption by utilizing a compact charger and power inverter to create an ultra-efficient backup power system for home and office use.ECO ModeIs an energy-efficient, user selectable feature for some surge-protected outlets. When the computer is off or is in sleep mode, the UPS automatically cuts power to computer peripherals connected to any outlets in ECO mode.LED Status LightsIndicate Power On, ECO on/off.PowerPanel® Personal SoftwareIncludes a free software download that provides a user-friendly dashboard interface for controlling and monitoring the UPS.ENERGY STARThis model is an ENERGY STAR® certified Uninterruptible Power Supply (UPS) system. ENERGY STAR is the trusted, government-backed symbol for energy-efficient products and practices that help save money and protect the environment.
Product OverviewThe CyberPower Smart App Online OL8KRTMB is a 6U rack/tower UPS featuring double-conversion topology for seamless power protection, an intuitive maintenance bypass switch design, and a pre-installed RMCARD205. Ensure maximum efficiency and capacity output with a Power Factor rating (PF) of 1. The energy-saving GreenPower UPS™ ECO Mode enables up to 96% efficiency while reducing power consumption and thermal dissipation. Smart battery management charging technology increases battery life up to 50% and replenishes battery charge from 0-90% in five hours.The OL8KRTMB enhanced LCD control panel functionality provides the ability to change the IP address, view UPS load energy consumptions, and select UPS diagnostic tests.Variable 4-speed fans provide automatic thermal management, based on power load, to reduce noise. A tamper-proof input circuit breaker ensures power is not turned off unexpectedly during service or maintenance. The OL8KRTMB simplifies installation with a quick start guide, user-friendly lifting straps, and an enhanced hanging rack mount rail system.The optional BP240VL3U01 Extended Battery Module expands runtime and speeds restoration of full backup power. The OL8KRTMB comes with a three-year warranty (including batteries) and a $300,000 Connected Equipment Guarantee.Double-Conversion TopologyProvides consistent, clean, and nearly perfect power, regardless of the condition of the incoming power. Never a need to switch to battery as DC power operates 100% of the time. Designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.Sine Wave OutputKeeps sensitive equipment with Active PFC working by preventing unnecessary shutdowns caused by gaps from simulated sine waves.Maintenance Bypass SwitchService or replace the UPS easily without powering down the connected equipment. The patented interlock bracket utilizes a color-coded security screw to simplify and reduce time for maintenance or module replacement.PowerPanel® Business Edition SoftwareProvides tools for easy remote monitoring and managing of the UPS and automates shutdown of multiple devices when needed.RMCARD205Enables remote management of up to 50 clients via a standard web browser, command line interface (CLI), or network management system (NMS) connection.LCD Control PanelDisplays UPS status data and configures operating settings from up to 10 ft. away (DB26 cable not included). The LCD control panel displays and allows configuration of IP address settings when an RMCARD205 is installed.Multiple Language OptionsThe LCD Control Panel can be configured in English, Spanish, French, and German for ease of use.Extended Battery Module (EBM)Extends runtime by adding up to 10 EBMs.Fast Charge TechnologyAllows UPS batteries to return to full capacity more rapidly by utilizing a built-in charger. Restores charge from 0-90% within five hours regardless of the number of EBMs.Smart Battery Management (SBM)Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.GreenPower UPS™ ECO ModeImproves UPS efficiency up to 96% reducing electrical and cooling costs.Hot-Swappable BatteriesKeeps equipment running by eliminating downtime during UPS power maintenance.Upgradeable UPS FirmwareKeeps equipment running by eliminating downtime during UPS power maintenance.Hanging Rack Mount RailEnsures easy installation and slides out safely with a safety catch.Tamper-Proof Input Circuit BreakerEnsures power is turned off using a tool to eliminate the risk of accidental powering off when not desired during service or maintenance.Critical & Non-Critical Load BanksMaximizes the output of the UPS by scheduling non-critical loads to shut off allowing additional runtime for critical load outlets.Emergency Power Off (EPO)Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.Generator CompatibleEnsures a stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.Converter ModeProvides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.USB & Serial ConnectivityEnables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.EMI/RFI FiltersPrevents electromagnetic and radio frequency interference to ensure clean power for connected equipment.Data-Line Surge ProtectionPrevents power surges traveling through telephone and Ethernet lines from causing damage to your equipment.Audible AlarmsIdentifies when the UPS is running on battery power, overloaded, or has a low battery.LED Status LightsIndicates Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.Rack/Tower VersatilityAllows for horizontal rack or vertical tower installation.Connected Equipment GuaranteeAffirms we will replace properly connected equipment if it is damaged by a power surge.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA