APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
-Toolless mounting capability.-Vertical mounting capability.-Rack-Mountable: Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.-Single input power source: Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.-Wide range of input and output connections: Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
"APC Basic Rack 1.8kVA. Product color: Black. Input connection type: NEMA 5-15P, Output connections: (10) NEMA 5-15R. Cable length: 144.1"" (3.66 m), Certification: cUL,CSA,GOST,METI Denan,UL 1363,UL. Nominal input voltage: 120 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 120 V. Dimensions (WxDxH): 17.6 x 2.24 x 1.73"" (447 x 57 x 44 mm), Weight: 5.51 lbs (2.5 kg)"
"APC Basic Rack 4.992kVA. Product color: Black. Input connection type: NEMA L6-30P, Output connections: (20) IEC 320 C13 (4) IEC 320 C19. Cable length: 120.1"" (3.05 m), Certification: cUL,CSA C22.2 No. 60950-1-03,METI Denan,UL 60950-1,UL. Nominal input voltage: 208 V, AC input frequency: 50 - 60 Hz, Load capacity: 4992 VA. Dimensions (WxDxH): 2.2 x 1.73 x 63.7"" (56 x 44 x 1619 mm), Weight: 12.3 lbs (5.57 kg)"
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
19 inch Rack-MountableSupplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternate power source.Resettable circuit breakersEnables a quick recovery from overload events.Vertical mounting capability.Horizontal mounting capability.
"APC Basic Rack 1.92kVA. Product color: Black. Input connection type: NEMA L5-20P, Output connections: (24) NEMA 5-20R. Cable length: 120.1"" (3.05 m), Certification: cUL,CSA C22.2 No. 60950-1-03,UL 60950-1,UL. Nominal input voltage: 120 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 120 V. Dimensions (WxDxH): 2.2 x 1.73 x 63.7"" (56 x 44 x 1619 mm), Weight: 10.7 lbs (4.86 kg)"
"APC Basic Rack 4160VA. Product color: Black. Input connection type: NEMA L6-20P, Output connections: (20) IEC 320 C13 (4) IEC 320 C19. Cable length: 120.1"" (3.05 m), Certification: cUL,CSA C22.2 No. 60950-1-03,UL 60950-1,UL. Nominal input voltage: 208 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 208 V. Dimensions (WxDxH): 2.2 x 1.73 x 63.7"" (56 x 44 x 1619 mm), Weight: 10.7 lbs (4.86 kg)"
Rack PDU 2G, Switched, ZeroU, 20A, 100-120V, (24) 5-20RAPC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.