"APC RBC23. Battery technology: Sealed Lead Acid (VRLA), Product color: Black. Weight: 5.31 lbs (2.41 kg), Dimensions (WxDxH): 2.7 x 6 x 3.7"" (68.6 x 152.4 x 94 mm)"
"APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within serverand/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level powermetering for power visibility and notification of potential overload. 4-in-1 combination outlets which canbe used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximumoutlet density with 42 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded and/orlabeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternatingphase design whereby each of the 3 phases are organized into small outlet groups which alternatefrom top to bottom of the PDU to facilitate better power cord management and promote better loadbalancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an NetworkManagement Card to continue functioning in the event of an AC power loss. No interruption in Networkcommunication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC)which can be replaced without powering down the PDU or connected devices to minimize downtimein the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at fullload ensures reliability and availability even in today's high density deployments. Gigabit ethernet toenhance and standardize network connectivity across all assets in the data center. A second ethernetport (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, orprovide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDUAdvanced to bill based on power usage. In addition, the higher level of accuracy ensures the mostprecise measures for capacity planning and threshold alarm monitoring. Two environmental sensorports allow for optional sensors (sold separately) to be connected. For data center deployments acrossmultiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally tosimplify and standardize deployment."
"APC SMART-UPS C LI-ION 500VA SHORT DEPTH 230V SMARTCONNECT. UPS topology: Line-Interactive, Output power capacity: 0.5 kVA, Output power: 400 W. AC outlet types: C13 coupler, AC outlets quantity: 4 AC outlet(s). Battery technology: Lithium-Ion (Li-Ion). Form factor: Rackmount/Tower, Product color: Gray, Rack capacity: 1U. Width: 17"" (432 mm), Depth: 9.13"" (232 mm), Height: 1.73"" (44 mm)"
APC Smart-UPS Modular Ultra External Battery Pack, 4 Battery Modules, Rackmount Lithium Ion (Li-Ion)
"APC RBC12. Battery technology: Sealed Lead Acid (VRLA), Product color: Black. Weight: 22 lbs (10 kg), Dimensions (WxDxH): 10 x 6 x 3.8"" (254 x 152.4 x 96.5 mm)"
"APC RBC33. Battery technology: Sealed Lead Acid (VRLA). Weight: 11.8 lbs (5.33 kg), Dimensions (WxDxH): 5.87 x 2.52 x 7.76"" (149 x 64 x 197 mm)"
"APC NetShelter Rack PDU Advanced, Switched, 11.5kW, 3PH, 415V, 20A, 520P6, 42 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.Maximum Outlet DensityAll models include 40, 42, or 48 outlets to accommodate even the highest density of devices, allow for more installation flexibility, and provide room for growth within the PDUs power capacity limits.Space SavingWith such high outlet counts and power capacity, NetShelter Advanced Rack PDUs are designed to maximize space with their single width form factor, often allowing for fewer PDUs to accommodate the same number of devices and power requirements.High Power CapacityModels now available to provide up to 34.6kW (derated to 80% capacity per National Electric Code (NEC) for North America) and up to 43.5kW for other countries to ensure support for most any density deployment and help minimize the number of PDUs needed to do so.APC Locking Power Cord CompatibleFree up space and secure power cords between rack-mount PDUs and attached IT equipment with this easy-to-use cord retention method. Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet; the ""locking"" feature is enabled when used with NetShelter Rack PDU Advanced to reduce the probability of accidental power cord disconnect.Circuit Breaker MonitoringAllows total load across each circuit breaker to be monitored for potential overload and can be configured to provide notification in the event of a circuit breaker trip.Alternating PhaseNetShelter Rack PDU Advanced incorporates an alternating phase design on 3 phase models whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU. This alternating phase layout facilitates better power cord management and more intuitive load balancing versus traditional PDU solutions where outlets are grouped by phase at the top, middle, and bottom of the PDU.60ºC (140ºF) Operating TemperatureRated and approved to operate up to 60C (140F) at full load, NetShelter Rack PDU Advanced ensures reliability and availability even in today's high density deployments.Power SharingRack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU. Network communication is uninterrupted, attached sensors still operate, and alarm traps remain available.Hydraulic Magnetic Circuit BreakersProvide increased availability by maintaining trip current over a wide temperature range.Live Swap Network Management CardThe Network Management Card (NMC) can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event.Color Coded OutletsTo simplify deployment, outlets on the PDUs are color coded by breaker on 1 phase models and color coded and/or labeled by breaker and input phase on 3 phase models.Environmental Sensor SupportTwo environmental sensor ports allow for optional sensors (sold separately) to be connected. Sensors available within the NetSelter Rack PDU Advanced portfolio include temperature, temperature/humidity, temperature (3 sensors)/humidity, rope leak detection, and a door contact switch. Also available is an expansion hub to allow connection of up to three sensors providing the ability to manage six separate sensors from one rack PDU. Sensor availability expected late 2022.Wide Offer BreadthMetered, Switched, and Metered-by-Outlet with Switching functionality are available across all power configurations ranging from 5kW up to 34.6kW to meet the need for most deployments.Network CascadingConnect and manage up to 32 PDUs from a single IP address to simplify and speed PDU deployment while reducing networking costs associated with having a dedicated network connection for each PDU.US Based ManufacturingUS based manufacturing enables better product availability and ability to offer configure-to-order (CTO) products (optional and subject to pricing and leadtimes) including different cord lengths, plug types, and PDU chassis color.Dual RatedFor data center deployments across multiple regions, select models are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.Flexible PDU MountingWith pre-installed mounting pegs, NetShelter Rack PDU Advanced can be quickly installed in the toolless mounting holes of the rear accessory channel in a NetShelter SX and many 3rd party cabinets. Mounting pegs can be repositioned to the side of the PDU to rotate the orientation of the outlets 90 degrees and face the back of the cabinet for better clearance from device chassis or mounting rails.4-in-1 Combination OutletsOffering unparalleled flexibility, 4-in-1 combination outlets which can be used as either C13 or C19 enable a single PDU outlet layout to support various rack layouts and configurations. In addition, the same 4-in-1 combination outlets also serve as high temperature C15 and C21 outlets for devices with C16 and C22 power cords. With 4-in-1 combination outlets redeployment of a PDU with new rack layout or configuration is easy and straightforward, often preventing the need to remove and discard a PDU upon IT refresh.Color LCD DisplayNetShelter Rack PDU Advanced provides a rich color LCD display for local management and control at the rack.Dual Network PortsA second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy.1% Metering AccuracyProviding the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring.Gigabit Ethernet ConnectivityProvides Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center.Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time."
APC APDU1335TH UPS accessory
NetShelter Rack PDU 10000 Temperature Sensor
Always stay online and prevent data lossAs soon as the power goes out, an APC Smart-UPS immediately provides emergency power to all connected equipment. Because an APC UPS does this automatically, you prevent unwanted failure of, for example, a PC, server or switch. With the free APC PowerChute software you can even have critical IT hardware shut down automatically and in a controlled manner when the battery of the UPS is almost empty. This way you prevent data loss, downtime and physical damage to hardware.SafetyIn addition, a Smart-UPS protects connected devices against peak voltage caused by lightning, among other things. This APC emergency power supply is ideally suited for (small) business use.Battery lifeYou can easily read the expected battery life in the runtime graph, which you can find between the product images. You can easily see how long the UPS supplies emergency power at a certain load.SmartConnectOut-of-box remote UPS monitoring, free for a 6-month trial period. Using the SmartConnect ethernet port, you can easily connect the Smart-UPS to your network and easily monitor it remotely via the secure APC SmartConnect cloud-based web portal*. In addition, the UPS can always be monitored via this port via EcoStruxure IT Expert (SFTWES1-DIGI).* Extend access to SmartConnect through the following licenses:1 year Standard Plan: ERWPMON1-1Y-DIGI3 year Standard Plan: ERWPMON1-3Y-DIGI1 year Advanced Plan: ERWPLUS1-1Y-DIGI3 year Advanced Plan: ERWPLUS1-3Y-DIGIPowerChuteBy connecting the UPS to a maximum of one server via a USB cable, it can automatically provide it with a shutdown signal during a prolonged power outage and thus prevent a hard shutdown. This exact moment can be set via the free APC PowerChute Serial Edition software.Network Management CardIf you connect the UPS directly to your network via the optional APC Network Management Card (AP9640/AP9641), it can easily be managed remotely via SNMP or our remote management software Ecostruxure IT Expert (SFTWES1-DIGI). You can also automatically send a shutdown signal via the network to multiple physical and/or virtual servers. By means of the APC PowerChute Network Shutdown Software associated with the network card can even be differentiated in the shutdown moment and the order in which this happens.Ease of useBy means of physical buttons and an LCD screen make it possible to set and read the basic functionalities.Extend the lifespanThe internal battery cartridge (RBC7) can be replaced easily, safely and independently by the user. This without having to switch off the APC SMT1500IC or connected equipment. This way you can easily and cheaply extend the lifespan of the APC Smart-UPS and your equipment always remains online.Warranty extensionThe manufacturer's warranty of the SMT1500IC is 3 years, with the exception of the battery cartridge, which has a 2-year manufacturer's warranty. Both are extended by 3 years to 6 and 5 years respectively with the APC service pack (WBEXTWAR3YR-SP-03).Switched Outlet Groups: Remote reboot and phased start-upThanks to the Switched Outlet Groups, it is possible to configure a phased/delayed power-on per UPS outlet group. This reduces the peak load on the UPS and brings it closer to the constant load, which limits oversizing of the UPS.It is also possible to reset a group of multiple UPS outputs and the equipment connected to them. If SmartConnect Advanced (ERWPLUS1-1Y-DIGI) is used, a UPS with SmartConnect port + Ecostruxure IT Expert (SFTWES1-DIGI) or a network card (ap9640) in combination with Ecostruxure IT Expert (SFTWES1-DIGI), this is even possible at a distance.Green PremiumThis label represents Schneider Electric's commitment to deliver products with best-in-class environmental performance. Green Premium promises to comply with the latest regulations, transparency on environmental effects and circular and low CO2 emission products.Green Premium:- Stands for an energy-efficient product that helps our customers achieve their CO2 reduction goals and save energy costs at the same time. The energy efficiency of this product is at least 10% higher than the market average.- Provides insight into the environmental effects of the product, this data is available 24/7 via the digital product environmental profile, see https://checkaproduct.se.com/- Commits to minimal use of hazardous substances within and beyond regulatory compliance (RoHS-/REACh)Maximize availabilityOr instead of extending the warranty, opt for the even more complete 5-year EcoCare Service to maximize the availability of your APC UPS. In addition to a 5-year warranty, it also includes 24/7 remote monitoring through the Schneider Electric Connected Services Hub and SE's on-site repair service (replacement parts, labor, installation and call-out charges).