Bypass an SUT40K UPS to Perform MaintenanceFor use with Tripp Lite’s SUT40K 3-phase UPS system, the SUT40KMBP maintenance bypass panel (MBP) maintains total continuity of power to connected load circuits when bypass of the UPS is required for regular service and maintenance. This UPS maintenance bypass panel has three 4-pole circuit breakers for Input, Bypass and Output. The breakers have removable handles to allow the panel’s trim cover to be removed for internal access. Maximum current capacity is 150A.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth and solid wall (mounting hardware not included).One-Year WarrantyThe SUT40KMBP is backed by a one-year limited warranty, ensuring reliability and performance.
Variable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Powerfully CompactOne unit provides precise temperature control to cool single racks of IT equipment without the need of any additional cooling systems.Rack Mount InstallationFrees up valuable IT floor space by placing the IT cooling at the bottom of any IT rack.Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Redundant ComponentsSingle points of failure in the system have redundant components to maintain availability and reliabiliEasy to installInnovative design allows for fast, easy installation by almost anybody.Modular designModular design provides scalable solutions to add cooling as demand increases.Vendor-neutral SolutionInstalls and integrates quickly and simply at the bottom of the IT rack. Ideal for existing/retrofit racks as well as new, pre-integrated racks.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Operational ServiceAllows critical components to be maintained/replaced while the system is in operation.
Rack system components that can be added to existing racks if requirements change.Includes: Installation Guide, Key(s), Slam Latches
APC ACAC10044 UPS accessory
NetShelter SX 18U 1070mm Deep Side Panel (Qty 1)
Eaton CBLADAPT48T UPS accessory
UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wall-mount three-breaker maintenance bypass panel is compatible with SVX180KL 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers – an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker – are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel’s trim cover to be removed for internal access. The 350A unit has a kAIC rating of 10K.Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).
UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wall-mount three-breaker maintenance bypass panel is compatible with Tripp Lite’s SV140KL7P and SV140KL8P 3-phase UPS systems. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers – an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker – are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel’s trim cover to be removed for internal access. The 600A unit has a kAIC rating of 10K.Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).
Eaton CBLADAPT96T UPS accessory
Eaton INDGW-M2 UPS accessory
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA