APC ACCD75214 evaporative air cooler Roof-mounted evaporative air cooler
Split Unit Outdoor Condensing Unit 6KW 208-230/1/60Split system units and integrated free-cooling systems for outdoor installationsAutomatic restartReturns the unit to its last operating status in the event of a power failure.Building Management SystemsUnits are designed to work with the most common BMS systems including BACnet and Modbus.Cost EfficientBudget conscious solution to enhance airflow within enclosureEasy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Zero White SpaceAll cooling equipment is placed outside the data center, allowing for valuable white space to be fully utilized for IT equipment.Scroll compressorsUtilize few moving parts for increased reliability and life expectancy.Dual power inputs(Optional) Dual power supplies for incoming power redundancyDirect Free CoolingUtilizes outdoor air when ambient air temperature can help support cooling loads.Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Service monitoringAll the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Building management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
Split Unit Ceiling Mount Evaporator 6KW 208-230/1/60Split system units and integrated free-cooling systems for outdoor installationsAir filtrationRemoves dirt and other particulates from the intake air for cleaner supply air.Automatic restartReturns the unit to its last operating status in the event of a power failure.Building Management SystemsUnits are designed to work with the most common BMS systems including BACnet and Modbus.Cost EfficientBudget conscious solution to enhance airflow within enclosureDirect Free CoolingUtilizes outdoor air when ambient air temperature can help support cooling loads.Dry contact outputProvides remote notification of failures when used with APC environmental monitoring unit or system.Dual fansProvides fault tolerance in the event of a fan failure.Ease of UseSimplifies future planning by allowing side to side equipment to be placed anywhere in the data center.EconomizationAchieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.Electronically Commutated FansProvide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.LED status indicatorsQuickly understand unit and power status with visual indicators.Microprocessor controllerThe system is controlled by a microprocessor, with an 80-character LCD backlit alphanumeric display, that provides communication and alarm indication.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Remote monitoring supportWeb-based service that serves as a second set of eyes into the health of a company's physical infrastructure. Experienced professionals work non-stop to provide 24-hour monitoring and to help diagnose problems before they become critical.Service monitoringAll the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.Temperature DisplayMonitors and displays temperature to prevent overheating.Scroll compressorsUtilize few moving parts for increased reliability and life expectancy.Dual power inputs(Optional) Dual power supplies for incoming power redundancyDirect Free CoolingUtilizes outdoor air when ambient air temperature can help support cooling loads.Active response controlMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.Service monitoringAll the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.Network interfaceProvides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Building management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA