This programmable Modbus card installs into select 3-phase UPS systems, allowing the UPS to communicate with a computer via RS-485 serial interface. The MODBUSCARDSV implements Modbus RTU protocol within Building Management Systems (BMS) and Industrial Automation Systems (IAS). It provides certain Modbus functions, such as Read Holding Registers and Write Single Registers. Dual sets of DIP switches (eight to a set) support Card ID and RS-485 configurations. compatible with SV Series (208V modular), SVX Series (400V modular), and 400V Monoblock SVTX, S3MX/XD Series UPS systems for status monitoring, configuration, control and email notifications.
UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wall-mount three-breaker maintenance bypass panel is compatible with SVT10KX 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers – an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker – are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel’s trim cover to be removed for internal access. The 40A unit has a kAIC rating of 10K.Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).
UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wall-mount three-breaker maintenance bypass panel is compatible with SVX150KL and S3M160KX 3-phase UPS systems. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers – an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker – are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel’s trim cover to be removed for internal access. The 300A unit has a kAIC rating of 10K.Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).
UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wall-mount three-breaker maintenance bypass panel is compatible with SVT20KX 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers – an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker – are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel’s trim cover to be removed for internal access. The 70A unit has a kAIC rating of 10K.Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).
UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wall-mount three-breaker maintenance bypass panel is compatible with SVX210KL7P, SVX210KL8P and S3M200KX 3-phase 200kVA and 210kVA UPS systems. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers – an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker – are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel’s trim cover to be removed for internal access. The 400A unit has a kAIC rating of 10K.Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.Convenient Wall-Mount InstallationMade of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).
APC Symmetra Accessories , Output: 230V , Output Connections: IEC 309,IEC 320 C19
Replacement dust filters for wide UPS cabinet.
Galaxy VS Seismic Kit for 1970mm tall UPS or modular battery cabinet.Seismic kit that includes anchoring brackets and anchors.
APC Symmetra RM XR Frame w/4 SYBT2, 220-240V: Cascading Capabilities, Hot Pluggable Operation, Hot Swap Batteries, Intelligent Battery Management, Rack Mount, Replace Batt Indicator, Status Indicator LED's
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA