120V 1U 10 OUTLETS
Add eight power outlets from a single power outlet in 1U of rack spaceThis 1U 8-Outlet Rack Mount Horizontal PDU features a built-in 8ft. (2.4m) NEMA 5-15P power cord and 8x NEMA 5-15R outlets, delivering 125V maximum input/output. With a 15A circuit breaker, this unit ensures the protection and stable operation of your critical equipment.Individual On/Off Outlet SwitchesEach outlet on the PDU is equipped with an independent/individual illuminated rocker switch, allowing for precise power management and control. The clearly enumerated switch labels make it easy to identify the switch to manage each connected device. Safety covers on the switches prevent accidental power cycling, adding an extra layer of security to the setup. This feature is particularly valuable in environments where uptime and equipment protection are paramount.15A circuit BreakerThe 1U 8-Outlet Rack Mount PDU features a robust 15 amp circuit breaker, designed to provide unparalleled protection for your connected equipment. This self-tripping and resettable breaker ensures that in the event of an overload or electrical fault, power is immediately cut off to prevent damage to your valuable devices. The 15A trip-point is precisely calibrated to handle the power demands of server rooms, data centers, and other professional IT environments, offering peace of mind and reliable operation. By swiftly interrupting the power supply in adverse conditions, this circuit breaker not only safeguards your equipment but also minimizes downtime and maintenance efforts, making it an essential component for any high-performance power distribution setup.1U Rack Mount DesignEngineered for compatibility, the 1U rack design easily installs into any 19-inch server rack that is four inches or deeper, utilizing just 1U of rack space. Adhering to ANSI/EIA RS-310-D standards, this horizontal-mount PDU is a perfect fit for any network rack, ensuring a streamlined and organized power distribution system.The PDU features an optimized design with heavy-duty steel housing and rear-facing outlets, maximizing space efficiency and durability, making it a reliable addition to any professional IT environment. Additionally, the attached 8 ft. (2.4m) power cord provides the flexibility and reach needed to accommodate various rack configurations, simplifying the setup process.The StarTech.com Advantage
"APC Basic Rack 2880VA. Product color: Black. Input connection type: NEMA L5-30P, Output connections: (24) NEMA 5-20R. Cable length: 120.1"" (3.05 m), Certification: cUL,CSA C22.2 No. 60950-1-03,UL 60950-1,UL. Nominal input voltage: 120 V, AC input frequency: 50 - 60 Hz, Nominal output voltage: 120 V. Dimensions (WxDxH): 2.2 x 1.73 x 63.7"" (56 x 44 x 1619 mm), Weight: 12.3 lbs (5.57 kg)"
Organize and add additional power outlets to your rack solutionThis 16-outlet (120V 15A)(12A UL) Rack PDU delivers a cost-effective power distribution solution for your server rack/cabinet. The 1U PDU can be mounted horizontally in any server rack 4in in depth or greater, to provide sixteen 120V 15A power ports/outlets, and features a rugged steel casing to ensure maximum durability.The front of the PDU features two LEDs that indicate proper ground and surge detection, while enabling you to control the power state with an illuminated power/reset switch.To prevent costly breakdowns of connected devices, the rackmount PDU features a built-in circuit breaker and reset switch, ensuring dependable performance of vital equipment.The StarTech.com Advantage
The PDUH30HV 5/5.8kW Single-Phase 208/240V Basic PDU is a versatile no-frills unit for data centers, server rooms and network wiring closets. Perfectly suited for high-density IT environments, the PDUH30HV features 10 total outletsβtwo in front and eight in the rear. The NEMA L6-30P input plug with 12-foot (3.6 m) cord connects to your facilityβs compatible AC power source, generator or protected UPS to distribute power to connected equipment.The switchless design prevents an accidental shutdown, which could lead to costly downtime. Dual 20A circuit breakers protect connected equipment from dangerous overloads. The reversible all-metal housing supports a variety of mounting options, including 1U horizontal or 0U vertical mounting in EIA-standard 19-inch racks, under a counter or on a wall or workbench.Reliable Single-Phase 30A 208/240V Power Distribution- Ideal no-frills PDU for data centers, server rooms and network wiring closets- 10 total C13 outletsβ8 rear and 2 front- NEMA L6-30P input plug with 12 ft. (3.6 m) power cord- Rear-panel grounding lug- Dual 20A circuit breakers protect against overloadsSwitchless Design- Prevents accidental shutdowns and costly downtimeVersatile Installation Options- Reversible all-metal housing faces front or rear in rack- Supports 1U horizontal or 0U vertical mounting in EIA-standard 19 in. racks- Also mounts on wall, workbench or under a counter
Product OverviewThe CyberPower PDU41101 is a 0U rackmount switched power distribution unit or PDU that has 24 outlets and provides 120V 20A output. This PDU distributes power to 24 NEMA 5-20R receptacles from a single NEMA (L)5-20P plug with unfiltered electrical pass-through. Using the CyberPower Management Console, a web browser, and the RJ45 Ethernet port for network connection, the user can manage the switched outlet receptacles individually or collectively over the network. In addition, the user can manage the switched outlet receptacles locally by using the LCD controls. Outlets can be turned on, turned off, or cycled on demand. The user can also schedule outlets to address a number of needs: remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads. The PDU41101 comes with a three-year limited warranty that covers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date.Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.Switch-Free DesignSafeguards against accidental power shutdown.Switchable OutletsProvides local and remote control for individual and multiple outlets. Local control: turn on/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on/turn off, schedule power on/off sequencing, and disable unused outlets.CyberPower Management ConsoleCyberPower Management Console is a hardware interface built into switched PDUs. Users can remotely switch individual PDU.Remote and Local MonitoringThe user is able to track PDU vitals both offsite and onsite. It also provides control to turn on/off individual outlets or circuits.Automatic Event NotificationsProvide immediate updates about power events via email, SMS text, or SNMP traps.Upgradeable FirmwareDownloadable firmware updates that provide improvements to programs that run the PDU.Power Control DisplayProvides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.Network-Grade Plugs and OutletsHighly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.Twist-Lock PlugThe user can secure the plug into an outlet by twisting and locking into place to prevent accidental disconnection.Long Input Power CordAllows the user to place the PDU where itβs needed because the power cord reaches distant power sources.Cord Retention TraySecures power cords. Keeps cord organized and accessible by securing power cord. The cord-retention tray also helps cords stay plugged in.Configurable Mounting BracketsAllows for installation of the PDU in the following configurations: 0U (vertical, under counter, and wall mount), 1U (horizontal, vertical, under counter, and wall mount), and 2U (horizontal and wall mount).
"Tripp Lite PDU121506. PDU types: Basic, Rack capacity: 0U/1U, Type: Single-phase. AC outlets quantity: 13 AC outlet(s), AC outlet types: NEMA 5β15R, Power plug: NEMA 5β15P. Cable length: 72"" (1.83 m). Nominal input voltage: 100 - 127 V, Maximum current: 15 A, AC input frequency: 50 - 60 Hz. Width: 20"" (508 mm), Depth: 4.5"" (114.3 mm), Height: 1.75"" (44.4 mm)"
Field-replaceable NMCIntegrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.High Retention OutletsWith no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.60C Operating TemperatureSelect 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).C13/C15 and C19/C21 Hybrid OutletsAvailable on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.Hydraulic Magnetic Circuit BreakersProvide increased availability by maintaining trip current over a wide temperature range.
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.- 120V 15A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 12A continuous)- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord- Digital display continuously reports total output power consumption in amps- 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth- 8 built-in NEMA 5-15R outlets- Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source- Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds- Built-in card slot supports optional SNMPWEBCARD for permanent upgrade to a switched & monitored PDU system- Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup- Front panel LEDs confirm power availability on both input lines- TAA Compliant Version Available - Order Tripp Lite PDUMH15ATAA
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.- 120V 15A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 12A continuous)- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord- Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface- Digital display continuously reports total output power consumption in amps- 8 switched NEMA 5-15R outlets- 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth- Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source- Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds- DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Compatible with optional ENVIROSENSE temperature monitor- Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized- Front panel LEDs confirm power availability on both input lines- TAA Compliant Version Available - Order Tripp Lite PDUMH15ATNETAA